Braun Pulse Oximeter
Braun Pulse Oximeter
This compact oximeter effectively measures blood oxygen levels and pulse rate.
-
In Stock
This compact oximeter effectively measures blood oxygen levels and pulse rate.
When the index finger is inserted into the fingertip photoelectric sensor of the low-power consumption, portable device, it will show the measured value of %SpO2, pulse rate, a vertical bar graph showing the pulse amplitude, as well as a wave graph showing the plethysmograph.
Take your health to the next level with HSA eligible Home Health Care products.
Benefits:
- Measures blood oxygen levels
- Monitors pulse rate
Features:
- Clinically validated accuracy
- Adjustable display orientation
- Back-lit OLED display
- Non-invasive, portable, and lightweight
- Auto power-off to conserve power
- Battery life indicator
- 1 year warranty
Size:
- Approximately L58mm × W35mm × H30mm
- Your finger must be clean for a proper reading.
- It is recommended that you use the oximeter on your index finger.
- Make sure your finger is fully inserted into the device and not pressed hard into a surface.
- Keep hands still while taking a reading as pulse oximeters are sensitive to motion.
- If your hands are cold or if you have poor circulation, warm your hands by rubbing them together or use another warming method before attempting to obtain a reading.
Please read the manual carefully before use.
The device isn’t suitable for continuous monitoring.
Poor blood circulation can result in inaccurate readings. A tourniquet, blood pressure cuff, other devices or clothing that cause blood flow restrictions may also result in inaccurate readings. Fingernail polish or acrylic nails obstruct the light transmission through the fingertip and may also result in inaccurate readings.
There are a number of other conditions which may lead to an inaccurate reading; including but not limited to, recent medical tests that included an injection of dyes, use of arterial catheters, a weak pulse, low levels of hemoglobin in the blood, low perfusion (the quality of your pulse), elevated levels of dysfunctional hemoglobin, the strength and type of light that you are in while using the pulse oximeter, and the existence of cell phones, radios, and fixed transmitters within certain ranges of the pulse oximeter during use.
This device does not provide a low SpO2 alarm.
DO NOT use on the same finger continuously for over 2 hours.
The device is not appropriate for the constant monitoring of the user. Prolonged and continuous monitoring may increase the potential of unexpected changes of dermal conditions. A feeling of discomfort or pain may occur if using the device continuously, especially for those users who experience poor perfusion or dermal abrasions.
In addition to the items described in the Warnings and precautions section, inaccurate measurements may be caused by factors including but not limited to: Immersing the device in liquid; Significant levels of dysfunctional hemoglobin (such as carboxyhemoglobin or methemoglobin); intravascular dyes such as indocyanine green or methylene blue; measurements may be adversely affected in the presence of high ambient light such as direct sunlight.
DO NOT modify this equipment without the authorization of the manufacturer.